10VRV / VRF systems

VRV / VRF systems for commercial buildings

Advanced multi-zone air-conditioning for larger spaces and buildings. Each zone can be controlled on its own, from one connected system. AI AIR SOLUTIONS designs, supplies, installs and services Daikin VRV systems from Raipur, across Chhattisgarh, Maharashtra and Odisha.

01The system

What a VRV / VRF system is

A VRV / VRF system connects one or more outdoor units to many indoor units through a single network of refrigerant piping. Instead of a separate outdoor unit for every room, one system serves a whole floor or building.

The system varies how much refrigerant goes to each indoor unit to match what each zone needs, so a meeting room, an open office and a cabin can each run at their own setting, or be switched off while the rest keeps running.

Indoor units on the same system don't have to be the same type: ceiling cassettes, concealed ducted units and ceiling-suspended units can share one network, chosen room by room for the ceiling and interior.

VRV or VRF: is there a difference?

They describe the same kind of system. VRV (Variable Refrigerant Volume) is Daikin's name for its systems; VRF (Variable Refrigerant Flow) is the general industry term used for this type of system by other manufacturers.

As a Daikin Authorized Dealer & Service Provider, the systems we supply and install are Daikin VRV. We also service VRF and other AC systems, including ones you didn't buy from us.

  1. 01

    Outdoor units

    Usually on the roof or a terrace, with clearance around them for airflow and room to service them.

  2. 02

    Refrigerant piping

    Insulated copper lines run from the outdoor units through shafts and ceiling voids to every floor.

  3. 03

    Branch joints

    Where the main line divides, branch joints split the refrigerant towards each indoor unit.

  4. 04

    Indoor units

    Cassettes, ducted or ceiling-suspended units in each zone, each with its own control.

3DSystem anatomy

VRV / VRF Systems

Multi-zone systems for larger spaces and buildings. Design, supply, installation and service.

  1. Step 01 / 07

    Outdoor unit

    Advanced multi-zone air-conditioning for larger spaces and buildings.

  2. Step 02 / 07

    Inside the unit

    Casing, fans, coil and compressor, drawn apart for a closer look.

  3. Step 03 / 07

    Refrigerant piping

    Insulated refrigerant lines carry the system into the building.

  4. Step 04 / 07

    Branching

    Multiple indoor zones on one system

  5. Step 05 / 07

    Indoor units

    Indoor units in each zone

  6. Step 06 / 07

    Air distribution

    Ductwork and diffusers carry conditioned air into the space.

  7. Step 07 / 07

    Every zone

    Each zone can be controlled on its own, from one connected system.

    Talk to an Expert

02Where it fits

Spaces where VRV / VRF is often considered

The final recommendation follows a conversation about your space. These are the spaces where we most often discuss it, and what we talk through for each.

03Before installation

Planning a VRV / VRF installation

A system like this is designed around the building, before anything is quoted. These are the questions we work through with you.

Planning guide
  1. 01

    Zones and how they are used

    Which rooms need cooling, how many people use them and at what times, and which areas must be controlled separately.

  2. 02

    Right-sized design

    Right-sized design before quotation: we calculate the cooling each zone needs, so the system is neither undersized nor oversized.

  3. 03

    Outdoor unit location

    A roof or terrace position with airflow clearance, a sound structural base and safe access for maintenance.

  4. 04

    Piping and drainage routes

    Where refrigerant lines can run through shafts and ceiling voids, and how condensate from each indoor unit will drain.

  5. 05

    Ceiling and interiors

    Whether each room has a false ceiling, which decides between cassette, ducted and ceiling-suspended indoor units.

  6. 06

    Service access

    Access panels and clear routes, so filters, units and joints can be reached for years of maintenance.

04How we deliver it

Design, supply, installation and service

One team from the first site visit to years of support.

  1. STEP 01

    Design

    We calculate your cooling needs properly, so you get the right system.

  2. STEP 02

    Sales

    Honest advice and clear proposals.

  3. STEP 03

    Installation

    Our own trained technicians install your system.

  4. STEP 04

    After-sales service

    Repairs, warranty support and yearly maintenance (AMC).

05After installation

Service, repairs and AMC for VRV / VRF

Multi-zone systems run for long hours in offices, hotels and hospitals. Planned servicing keeps them dependable, and faults are found and fixed by people who understand the whole network.

Serving Chhattisgarh, Maharashtra, Odisha from Raipur. Read more about AC maintenance and AMC.

→Talk to an expert

Planning a new space or replacing your AC system?